Instrument Channel DryerStudies indicate there is a strong correlation between moisture and microbe colonization within flexible endoscopes. The Airtime Instrument Channel Dryer dries flexible endoscope channels, as well as channels in other cannulated surgical instruments. A scope removed from the AER can be dried quickly, so it will not be stored, or put into immediate use, with wet channels. Two models are available, Variable Flow Rate Unit (VFR100) and External Air Supply Unit (ATEAS01). |
Introducing the Airtime Variable Flow Rate Unit (VFR100)The Airtime Variable Flow Rate Unit (VFR100) automatically adjusts airflow, maximizing the amount of air fed into channels, without the risk of overpressurizing the instrument. By continuously monitoring channel pressure, VFR100 will increase or decrease airflow based on the instrument manufacturer’s PSI rating. This process not only protects valuable instruments, it also minimizes drying times. Drying cycles are automatically and immediately shut off in the event of a clogged or collapsed instrument channel. |
VFR100 Features:
|
Airtime External Air Supply (ATEAS01)The Airtime ATEAS01 is a pumpless channel dryer that utilizes the facilities wall supplied Instrument Air. Air flow and channel pressure are continuously monitored throughout the drying cycle, preventing overpressure in delicate instrument channels. Instrument PSI sensor settings and drying cycle times are managed with two independent touch screens. The extreme dryness of Instrument Air (-40 F) helps reduce overall drying times. The two air filters at the base of the ATEAS01 unit provide added .01 micron filtration prior to the air entering the instrument. This ensures that any particles that may have been trapped in the facilities airlines will not reach the instrument. |
Variable Flow Rate Dryer (VFR100) shown here on Counter Stand. | Independent timers for each pump. |
External Air Supply Dryer (ATEAS01) shown on Wall Rail. |
Adapters & TubingAirtime tubing and adapter sets provide maximum flow rate and reduced drying times for a variety of instrument types. To reduce the risk of cross-contamination between instruments, tubing sets are changed monthly, and adapter sets are changed after each use. Compatible with Olympus, Pentax, Fuji, Storz, ACMI, and Intuitive Surgical. Ask your Cygnus Rep for detailed adapter and tubing information. |
SKU | DESCRIPTION | SIZE | UNITS/CASE |
---|---|---|---|
Airtime Controllers | |||
VFR100 | Airtime™ Instrument Channel Dryer Variable Flow Rate Unit |
6" W x 10" H 3.25" D | 1 |
ATEAS01 | Airtime™ Instrument Channel Dryer External Air Supply |
6" W x 10" H 3.25" D | 1 |
Adapter Sets | |||
ASO3 | Adapter Set for Olympus flexible endoscopes, includes 1 Suction Tube Adapter, 1 Suction Port Cap, 1 Air/Water Adapter, 1 Biopsy Port Cap, & 1 Auxiliary Water Jet Port Adapter. | For use with Olympus flexible endoscopes. | 120 sets |
ASP2 | Pentax Adapter Set for Pentax flexible endoscopes, includes 1 Suction Tube Adapter, 1 Suction Port Cap, 1 Air/Water Adapter, 1 Biopsy Port Cap, & 1 Auxiliary Water Jet Port Adapter. | For use with Pentax flexible endoscopes. | 120 sets |
ASF2 | Adapter Set for Fuji flexible endoscopes, includes 1 Suction Tube Adapter, 1 Suction Port Cap, 1 Air/Water Port Adapter, 1 Biopsy Port Cap, & 1 Auxiliary Water Jet Port Adapter. | For use with Fuji flexible endoscopes. | 120 sets |
ASOB1 | Adapter Set for Olympus bronchoscopes, includes 1 Suction Port Adapter & 1 Biopsy Port Adapter. | For use with Olympus bronchoscopes. | 100 sets |
LL01-01 | Luer Lock Adapter and Luer Lock Cap (individually packaged pairs), 1 adapter/cap pair per bag, 100 bags per case. 100 pairs total. | For use with small diameter instruments. | 100 pairs |
LL01-25 | Luer Lock Adapter with Luer Lock Cap (bulk packaged pairs, 25 adapter/cap pairs per bag, 4 bags per case. 100 pairs total. | For use with small diameter instruments. | 100 pairs |
LL02-01 | Luer Lock Adapter and Suction Tube Adapter (individually packaged pairs), 1 luer lock/suction tube pair per bag, 100 bags per case. 100 pairs total. | For use with small diameter instruments. | 100 pairs |
LL02-25 | Luer Lock Adapter and Suction Tube Adapter (bulk packaged pairs), 25 luer lock/suction tube pairs per bag, 4 bags per case. 100 pairs total. | For use with small diameter instruments. | 100 pairs |
Tubing Sets | |||
DF100X | Airtime™ Directional Flow Tubing Set | Universal with appropriate adapters. | 20 |
HDF200X | Airtime™ Horizontal Drying, Directional Flow Tubing Set. Used for drying coiled scopes. | For use with Olympus Adapter Set ASO3, Pentax Adapter Set ASP2, & Fuji Adapter Set ASF2. | 20 |
SDT01 | Airtime™ Small Diameter Scope Tubing Set, single-line. Two tubing sets per unit. | N/A | 5 |
SDT02 | Airtime™ Small Diameter Scope Tubing Set, dual-line. Two tubing sets with Y connector per unit. | N/A | 5 |
SDT03 | Airtime™ Small Diameter Scope Tubing Set, dual-line. Two tubing sets with straight-line adapter fitting. | N/A | 5 |
Filters | |||
FLT-Y30 | Airtime™ HEPA Filter Assembly Set, .010 µm right angle connector |
N/A | 2 |
FLT-Y40ST | Airtime™ HEPA Filter Assembly Set, .010 µm straight line connector |
N/A | 2 |
IV Pole Installation | |||
IV500 | Airtime™ IV Pole Set includes: 1 cradle bar, 2 height reduction bars, 1 mounting bracket and 1 IV pole. | N/A | 1 |
Counter Stand Installation | |||
CS9179 | Airtime™ Counter Stand with Universal Mounting Bracket |
9" W x 17" H x 9" D | 1 |
Wall installation | |||
WRC100 | Airtime™ 12" Wall Rail Mounting System, use to mount 1 Airtime Control Unit. Includes a 12" rail with 2 white end caps, 2 wall mounting anchors, and 1 universal wall rail bracket. | 12" Rail | 1 |
WRC200 | Airtime™ 24" Wall Rail Mounting System, use to mount 2 Airtime Control Units. Includes a 24" rail with 2 white end caps, 2 wall mounting anchors, and 2 universal wall rail brackets. | 24" Rail | 1 |
WRC300 | Airtime™ 36" Wall Rail Mounting System, use to mount Airtime Control Units or flexible endoscopes. Includes a 36" rail with 2 white end caps, 3 wall mounting anchors, and 8 universal wall rail brackets and scope cradles. | 36" Rail | 1 |
WRC500 | Airtime™ Complete Wall Rail Mounting System – Proper installation requires wall space that is 3' 6” wide by 80” high. The system will hold two scopes and one Airtime Control Unit. It includes four – 3 foot rails with white end caps, 12 wall mounting anchors, 9 universal wall rail brackets and 8 positioning bars. The positioning bars are used for holding the scope and for height reduction. | N/A | 1 |